 S/MOD/SKH20240/C/3/05/2007
Relais Statique pour circuit imprime Solid State Relay for printed circuit board
* Gamme pour circuit imprime avec radiateur integre. * Sortie AC synchrone. * Calibre thyristors : 25A * Technologie thyristors et DCB ( Direct Copper Bonding) * Range for printed circuit board with integrated heatsink * Zero-cross AC Output. * Thyristors size : 25A. * Thyristor and DCB technology ( Direct Copper Bonding)
Ces produits sont disponibles avec d'autres tailles de thyristors :16A , 50A/1800A2s et 75A/5000A2s pour de tres hautes performances. These products are available with other sizes thyristors: 16A ,50A/1800A2s and 75A /5000A2s for high performances. DIMENSIONS * :La limite du produit est 10A @25C en air tolerances 0,2mm 22 calme et peut atteindre 25A en regime 43,6 12,7 ventile avec le radiateur limite a 85C. The product limit is given at 10A @25C with convection cooling and can reach 25A in forced celduc SKH air at a case of temperature of 85C.
28 24,2 35,7
43 2 1
page 1 / 3 F/GB
SKH20240
8-32VDC control 10A*/ 400VAC output
Application typique/Typical application
Ph
Ph
SK model VDR on the PCB Ou / Or SK model VDR on the PCB
6,3 1,73
7,5
O1 5,08 12,7 10,16 7,83
Charge / Load
3+
Rc Ic
SSR
1~
Charge / Load
Top view
Uc
42~
2,54 Trou / Hole O 1,6
SSR
N N
Caracteristiques de commande (a 20C) / Control characteristics (at 20C) DC Parametres / Parameters Symbol Min Nom Tension de commande / Control voltage Uc 8 24 Courant de commande / Control current (@ Uc nom ) Ic 3,5 13,5 Tension de relachement/Release voltage Uc off Resistance interne / Input internal resistor fig.1 Rc 1640 Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Tension assignee Isolement/Rated impulse voltage Uimp 4 000 Isolement entree-sortie / Input-output isolation U 4000 Isolement E-S/semelle/ I-O/ case U 3300
fig. 1 :Caracteristique d'entree / Control characteristic Max 32 18 1 Unit V mA V V VRMS VRMS
21 18 15
Ic (mA)
12 9 6 3 0 02 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Uc (V)
Caracteristiques generales / General characteristics Parametres / Parameters Poids/Weight Temperature de stockage / Storage temperature Temperature de fonctionnement / Operating temperature Conditions Symbol Typ. 30 -40/+120 -40/+80 Unit g C C
celduc
All technical characteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
r
e
l
a
i
s
S/MOD/SKH20240/C/3/05/2007
page 2 / 3 F/GB
Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parametres / Parameters Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete / Peak voltage Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal / Nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) EMC Test d'immunite /Conducted immunity level: with external VDR EMC Test d'immunite /Conducted immunity level : with external VDR Conformite / Conformity Homologation / Approbal Fig.2 Caracteristiques thermiques / thermal curves : Conditions Symbol Typ. Unit Ue 400 V rms Uemin-max 24-600 V rms Up 1200 V Usync 12 V Ua 8 V Ie 25 (*) A rms Itsm 300 A Vd 1,6 V Ilk 1 mA Iemin 5 mA ton max 10 ms toff max 10 ms f 10-440 Hz dv/dt 500 V/s di/dt 50 A/s I2t 450 A2s 2kV criterion A with external VDR 2kV criterion A with external VDR / pr EN61810-xxx UL pending
Ie nom tp=10ms (Fig. 3) @ Ie nom @Ue, 50Hz Uc nom DC ,f=50Hz Uc nom DC ,f=50Hz
IEC 1000-4-4 (bursts) IEC 1000-4-5 (shocks) EN60947-4-x and 5-1
* : / Limite par le radiateur et le circuit imprime / limited by the heatsink and the printed circuit board
26 24 22 20 18 16 14 12 10 8 6 4 2 0
I max = f(tambient)
Ventilation forcee avec temperature du dissipateur limitee a 85C./ Forced air cooling with heatsink temperature 85C max
I (A)
Convection naturelle/ Convection cooling
0
10
20
30
40
50
60
70
80
90
100
Ambient temperature ( C)
Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge. * Prevoir un varistor externe en parallele sur la sortie : taille mini : 14mm Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains. * Use a VDR across the output : minimum size : 14 mm
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19
S/MOD/SKH20240/C/3/05/2007
page 3 / 3 F/GB
Surge current Itsm (A peak) = f(t) for models with Itsm =300A 300 Itsm (Apeak)
No repetitive Itsm (Apeak)=f(t) without voltage reapplied
200 100 0
Repetitive Itsm (Apeak)=f(t) with voltage reapplied for initial Tj =70C
0,01
fig 3
0,1 t (s)
1
10
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19


▲Up To Search▲   

 
Price & Availability of SKH20240

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X